The floor distribution control Standard controls motor control units for up to 4 facades or groups via a higher-level central control unit or for facades with operation on different stories.

All-round

Control per channel or per facade with 4 outputs. You can control up to 4 facades or grouped motor control units per level.

Safe

Your move command is only executed for as long as the push button is actuated. This ensures a so-called "dead man operating mode".

Simplified

The system optimises the wiring required in complex buildings thanks to its clear layout.

  • Floor operation of up to 4 facades via connectable venetian blind switches
  • Dead man operating mode executes move command as long as the switch is actuated
  • Supplies power to control devices without an integrated power supply unit (e.g. MSE Piccolo, Uniswitch ZL)
  • 4 non-floating outputs (24 V DC, max. 2 A)
Article number: 1002253

Description

Value

Operating voltage

230 V AC

Control voltage

24 V DC

Output

4 x 24 V DC

Switching capacity per drive

2 A at 24 V DC

Logic behaviour

Dead man

Degree of protection

IP 54

Safety class

II

Type of installation

Surface-mounted (AP)

Width

240 mm

Height

160 mm

Depth

90 mm